Add to Favorites
Share

Ionic Earth | Grounding Electrodes | Rod | Bar

  • Description
Product Detail

    Electrolytic Ion Earthing Pole


    Model

    Overall dimension

    Remarks

    JHY-15

    F54×1500mm

    One 1500mm long linear type

    JHY-25

    F54×2500mm

    One 2500mm long linear type

    JHY-30

    F54×3000mm

    One 3000mm long linear type

    JHY-45

    F54×4500mm

    Combination of three 1500mm long linear or L-shape type

    JHY-60

    F54×6000mm

    Combination of four 1500mm long linear or L-shape type


    blob.png 

    Advanced conductive ionic compound is selected and the electrode is covered with red copper so as to guarantee good conductivity and anti-corrosion property.
    Expansibility, absorptivity and ionic permeability of the backfill material are good and the resistance reducing effect is obvious.
    Excellent moisturizing property guarantees long-term stable and reliable resistance value.


    ??53_??(001).jpg

    blob.png  

    JHY electrolytic ionic earthing electrode is made of red copper pipe and the standard length of earthing electrode is 3M. Two pieces of 1.5M long electrodes are connected by the middle connector and required length and shape can be made. Under normal circumstances, the electrode has two types: linear type and L-type. In special cases, for example, the construction area is too narrow to satisfy the high requirements of earthing resistance. At this time, the earthing electrode can be extended infinitely by using the connector until the requirements are met.


     
    blob.png  

    JHY electrolytic ion earthing electrode is able to absorb air and moisture in soil through the top air pore, so that the chemical compound in the earthing electrode will be deliquesced and electrolytic ions are produced and released into the surrounding soil; the surrounding earth is actively regulated to reduce the resistivity of soil to the minimum; as a result, the conductivity of the earthing system will remain at relatively high level. The specially-made backfill material has satisfactory expansibility, absorptivity and ionic permeability, which not only guarantees that the electrode and soil always contact closely with each other to reduce contact resistance but also the surrounding temperature of electrode is effectively maintained and auxiliary conductive function of electrolytic ion is improved; as a result, the most stable effect of the earthing system is guaranteed. Moreover, the backfill material is not corrosive and will not cause pollution to surrounding environment.??51_??.jpg 


    blob.png  

    JHY electrolytic ion earthing electrode is applicable to different geological conditions including black soil, loess, saline-alkali soil, garbage soil, backfill, weather sandy soil, fine sand dust, clay and earth and satisfactory earthing resistance reducing effect can be achieved through high-quality construction technology. The earthing electrode is widely applied to different fields such as electric power system, communication system, petrochemical system, broadcast & television system, construction works and medical treatment facilities.



    ion system

    traditional process

    working mechanism

    by the icon release effect from filling materials inside and outside the pole, contact environment from pole and surrounding soils are improved so that resistance reduction purpose is achieved.

    Resistance is reduced by laying of tremendous metal material and earthing resistance is achieved by common earthing method

    earthing stability

    The filling materials outside are good in corrosion resistance, water absorption and humidity holding. It is free from climate influence. Earthing resistance can go into stable status one week after construction is completed. It is free from influence of dry or humid solids and will not go up as time goes by

    1. Dry contact, the earthing resistance varies a lot when its dry or humid

    2. Earthing resistance will go up quickly as time goes by due to corrosion

    life span

    It is corrosion resistance and icon will be supplied automatically when in shortage so life span is more than 30 years.

    Bad performance in corrosion resistance. Soil construction is needed to be redone every three or five years to reduce soil resistivity

    project process

    professional process. The resistance reduction performance are good and construction is simple. So the project work is less and cost is low

    Low technologies, tremendous project work, no quality guarantee from process 


    C.working principle
    JINHEYI brand—electrolytic ion earthing pole are added with reversible slow release filling agent . This agent has characteristics such as water absorption, water release  and reversion. When it absorbs water, it can absorbs 100-500 times of its own water. When outer environment is dry and needs water, the water can be released completely so that the water is balanced for surrounding areas. This is reversible reaction which effective humidity inside the casing body is guaranteed and stability of earthing resistance is ensured. By this method of icon water absorption and deliquescence, electrolytic ion is released effectively to surrounding soils so that the earthing pole is acting like a icon production device so as to improve the surrounding soils to achieve the earthing requirements. The outside filling agent of earthing pole is creating chemical treatment for casing soils by the interaction of internal electrolytic icon filling agent to reduce the resistivity for casing soil. At the same time, a transition band is formed between release earthing pole and soils so that contact area is increased between section area of earthing pole with same efficiency and soils and contact resistance between earthing unit and soils is eliminated and the electric field distribution in the soil is improved. The filling agent is good in penetration and can root into nuds and cliff gap so as to form a tree root network and increase the effusion acreage from soils

    ??54.png

    1?JINHEYI brand—electrolytic ion earthing pole 

    2?current soil

    3?special filling agent

    4?icon distribution to surrounding area

    5?conducting scope is increased in land

     

    E. design method and usage reference
     1.?˜ 2R 
     ?--average soil resistivity
     R-- grounding resistant from current land net
     S-- coverage of current combined land net 


     2.   n ˜ 0.0275 * ? / R-0.4
     N-- is numbers of electrode needed for grounding
     ?-- soil resistivity
     R-- max value for grounding resistance 


     3.design guide

         numbers of electrode(pcs)
         Grounding Resistance O

    1

    2

    3

    4

    Land Resistance O.m

    100

    <1.9

    <1.1

    <0.7

    <0.5

    200

    <2.9

    <2.3

    <2.0

    <1.1

    300

    <5.9

    <3.4

    <2.5

    <1.7

    400

    <7.9

    <4.6

    <3.3

    <2.3

    500

    <9.9

    <5.8

    <4.2

    <2.9

    600

    <11.8

    <6.9

    <4.9

    <3.5

    700

    <13.8

    <8.1

    <5.8

    <4.0

    800

    <15.8

    <9.3

    <6.6

    <4.7

    900

    <17.8

    <10.4

    <7.4

    <5.2

    1000

    <19.8

    <11.6

    <8.3

    <5.9


    F. application and method of use
    JINHEYI brand—electrolytic ion earthing pole is good in corrosion resistance and nice in conducting performance and unique in design process, so they are widely used in important sides for earthing projects such as telecommunication, power ,electricity industry, petrochemical fields, finance, network and electricity, especially where the soil conditions are really bad and construction conditions are limited and high technologies are required construction method. 


    1.hole drilling:
    Drilling  a vertical hole with diameter of 160mm×3150mm/1550mm in a good construction site.
    2.filling agent formulated:
    Use water to blend filling agent like paste(slight thick,but showing like liquid) and pore into the drilled hole and depth is about the bore position. 
    3.embed earthing pole:

    (1)open earthing pole sealing tape;
    (2)embed earthing pole into hole, top of earthing pole is same flat as earth;
    (3)connecting down lead;
    (4)fill the rest of filling agent on the surrounding of earthing pole until it arrives 100mm on top of earthing pole. Measure the earthing resistance and if it reaches earthing requirement, use soil to cover electrode surroundings.

     
    Notes: When one set of earthing pole cannot meet resistance requirement, you can use two sets of parallel connection from several sets. The distance between rods should not be less than 5M; Outgoing lines should be used with 50mm2 copper wire strand. Crimp connection is done for outgoing lines and earthing poles. The connecting points should be treated with corrosion resistance.